Digital Load Cell Weight Sensor HX711  + DISC KIT – KSH 400 at HIMA TRONICS Mombasa – Top quality HIMA electronics. Best electronics in Kenya. Shop now for Arduino, ESP32, sensors and IoT devices.

Digital Load Cell Weight Sensor HX711 + DISC KIT

SKU: HMJ783 Category: HIMA electronics
KSH 400.00
Out of Stock
Inquire
Product Description

Digital Load Cell Weight Sensor HX711 + Disc Kit

= High-Precision Weighing Kit for Arduino Projects =

This kit combines a highaccuracy load cell with an HX711 24bit ADC module, providing a complete solution for building digital scales and force measurement systems with Arduino.

24Bit Precision HX711 ADC with built-in 128x gain amplifier
Complete Kit - Load cell, HX711 module, and hardware included
Operating voltage is 3.3V to 5V - compatible with most boards
Select 10SPS or 80SPS data rate for precision or speed
Do not exceed load cell maximum weight rating

= Technical Specifications =

ParameterValue
Load Cell Capacity5kg (11lbs)
ADC Resolution24-bit
Gain Options128x, 64x, 32x
Supply Voltage3.3V to 5V
Communication2-wire (DOUT/SCK)
Output Data Rate10SPS or 80SPS

= Key Features =

High Precision 24bit conversion for accurate readings

Complete Solution - Load cell and amplifier included

Dual Voltage Support - 3.3V and 5V compatible

Simple Interface 2wire communication

Auto Calibration - Software support for easy setup

== Applications ==

  1. Digital bathroom scales
  2. Kitchen and food scales
  3. Industrial process monitoring
  4. Force measurement systems
  5. IoT weight tracking devices
Widely Used - Standard Arduino weighing solution
Easy Integration - Many libraries available

√ Mounting hardware included

√ Pre-assembled and tested

√ Great for STEM education

= Connection Guide =

Load cell wiring:

  • Red: E+ (Excitation positive)
  • Black: E- (Excitation negative)
  • White: A- (Signal negative)
  • Green/Blue: A+ (Signal positive)

HX711 to Arduino:

  • VCC: 5V or 3.3V
  • GND: Ground
  • DT: Digital pin
  • SCK: Digital pin
Fix one end of sensor, apply load on the other
Calibrate with known weight for accuracy
Do not apply pressure on white glue-coated part
Protect from moisture and shock

= Calibration Instructions =

For accurate readings:

  1. Perform tare (zero without load)
  2. Place known reference weight
  3. Calculate scale factor in software

Simple Digital Control - Easy calibration process

Memory Function Settings save after poweroff

Used in professional electronic scales
Reliable and repeatable measurements

√ Library examples available

√ Supports multiple load cells

= Troubleshooting =

No readings:

  • Check wiring connections
  • Verify power supply
  • Avoid loose connections

Inconsistent readings:

  • Perform calibration
  • Check mechanical mounting
  • Avoid external vibrations